Penilaian Kenyamanan Termal pada Ruang Baca Perpustakaan Umum Kota Pekalongan

Authors

  • Astrihasna Shafa Universitas Diponegoro
  • Suzanna Ratih Sari Universitas Diponegoro

DOI:

https://doi.org/10.21776/ub.ruas.2022.020.01.3

Keywords:

thermal comfort, library, perception

Abstract

Evaluation of thermal comfort in the 1st and 2nd-floor reading rooms of Pekalongan City Public Library is to support the aim of designing a comfortable reading room that can increase people's reading interest. This study uses a quantitative approach defined descriptively and evaluatively. Direct measurement data in the morning and afternoon using a thermometer, hygrometer, and anemometer for four days. Data also uses a questionnaire. The collected data compares the measurement analysis results with recommended standards. The result shows that the reading room on the 1st floor was in the threshold and heat-comfort category, which was around 26℃ - 27.4 ℃, while the reading room on the 2nd floor was in the optimal comfortable category, which was around 24.7℃ - 26.4℃. The effective temperature of the 1st-floor reading room is higher than the 2nd floor. The final result shows that the room is in the less comfortable category because the air conditioner in the reading room is not as it should be appropriate.

Author Biographies

Astrihasna Shafa, Universitas Diponegoro

Program Studi Magister Arsitektur, Fakultas Teknik, Universitas Diponegoro

Suzanna Ratih Sari, Universitas Diponegoro

Program Studi Magister Arsitektur, Fakultas Teknik, Universitas Diponegoro

References

Elbes, R., & Munawaroh, A. S. (2019). Penilaian Kenyamanan Termal pada Bangunan Perpustakaan Univrsitas Bandar Lampung. ARTEKS: Jurnal Teknik Arsitektur, 4(1), 85-98.

Istiningrum, D. T., Arumintia, W. S. R. L., Mukhlisin, M., & Rochadi, M. T. (2017). Kajian Kenyamanan Termal Ruang Kuliah pada Gedung Sekolah C Lantai 2 Politeknik Negeri Semarang. Wahana : Teknik Sipil, 22(1), 1-16.

Lippsmeier, G. (1994). Bangunan Tropis. Jakarta: Erlangga.

Muliyadi, I. (2013). Penggunaan Air Conditioner Sebagai Aspek Pencegahan Terhadap Kerusakan Bahan Pustaka. Khizanah Al-Hikmah, 1(2), 131-137.

Prianto, E., & Depecker, P. (2003) Optimization of Architectural Design Elements in Tropical Humid Region with Thermal Comfort Approach. ELSEVIER, 35(3), 273-280.

Qodir, A., Setyowati, E., & Suryono. (2020). Analisis Pengaruh Bentuk Serambi Masjid Terhadap Kenyamanan Termal Adaptif. Jurnal Arsitektur ARCADE, 4(3), 261-268.

SNI 03-6572-2001. Tata Cara Perancangan Sistem Ventilasi dan Pengkondisian Udara pada Bangunan Gedung. Jakarta: Badan Standarisasi Nasional.

Syukron, M. (2015). Pengaruh Pelayanan Perpustakaan Terhadap Minat Berkunjung Anggota Perpustakaan Umum Kota Pekalongan. Skripsi : IAIN Pekalongan.

Wulandari, S. D., & Wibawa, B. A. (2020). Analisis Kenyamanan Termal pada Ruang Baca Perpustakaan Universitas PGRI Semarang. SENS 5 : Science and Engineering National Seminar 5, 5(1), 418-424.

Downloads

Additional Files

Published

2022-06-29

How to Cite

Shafa, A., & Sari, S. R. (2022). Penilaian Kenyamanan Termal pada Ruang Baca Perpustakaan Umum Kota Pekalongan. RUAS, 20(1), 23–32. https://doi.org/10.21776/ub.ruas.2022.020.01.3

Issue

Section

Articles