Adaptasi Kinerja Bangunan Rumah Tinggal dengan Ventilasi Atap Responsif

Authors

  • Mufidah Mufidah UNTAG SURABAYA
  • LMF. Purwanto Unika Soegijapranata Semarang
  • Ridwan Sanjaya Unika Soegijapranata Semarang

DOI:

https://doi.org/10.21776/ub.ruas.2021.019.01.7

Keywords:

passive design, humid tropics, responsive roof ventilation

Abstract

Thermal comfort is a condition where occupants can feel comfortable doing activities in the building. One of the ways to get comfort is done by passive design, in which the building is designed to adapt weather change outside the building. Because the weather outside is always changing, the planned building design must be responsive to these weather changes. This study uses a responsive roof ventilation model, that the movement of the roof vent covering grille, which serves as an attempt to regulate the exit of wind from the inlet. This study method begins with a literature review on the thermal comfort of residential building in the humid tropics,  as a study of the application of passive design principles as building adaptation to weather changes. Furthermore, an analysis of the ventilation area is made based on the need for thermal comfort in the building. Finally, the planning of building performance systems automatically using the Arduino temperature and humidity sensors. The result is the concept of a framework as applying automation to responsive roof ventilation. This preliminary study is still basic and it is hoped that can be continued in research with the application and experimentation of the roofs in small building

Author Biographies

Mufidah Mufidah, UNTAG SURABAYA

Program Studi Arsitektur, Fakultas Teknik, Universitas 17 Agustus 1945 Surabaya

LMF. Purwanto, Unika Soegijapranata Semarang

Program Studi Doktor Arsitektur, Fakultas Arsitektur dan Desain, Unika Soegijapranata Semarang

Ridwan Sanjaya, Unika Soegijapranata Semarang

Program Studi Doktor Arsitektur, Fakultas Arsitektur dan Desain, Unika Soegijapranata Semarang

References

Alfata, M. N. (2011). STUDI KENYAMANAN TERMAL ADAPTIF RUMAH TINGGAL DI KOTA MALANG, Studi Kasus : Perumahan Sawojajar 1- Kota Malang. Jurnal Permukiman, 6(1), 9–17.

Amri, S. B., & Syukur, L. O. A. (2017). Analisis Aliran Angin Pada Atap Miring Melalui Uji Simulasi Flow Design. Langkau Betang: Jurnal Arsitektur, 4(2), 136. https://doi.org/10.26418/lantang.v4i2.23252

Aynsley, R. M. (1977). Architectural Aerodynamics. Applied Science Publishers.

Bainbridge, D., & Haggard, K. (2012). Passive solar architecture: heating, cooling, ventilation, daylighting and more using natural flows. In Choice Reviews Online (Vol. 49, Issue 05). Chelsea Green Publishing. https://doi.org/10.5860/choice.49-2689

Friadi, R., & Junadhi, J. (2019). Sistem Kontrol Intensitas Cahaya, Suhu dan Kelembaban Udara Pada Greenhouse Berbasis Raspberry PI. Journal of Technopreneurship and Information System (JTIS), 2(1), 30–37. https://doi.org/10.36085/jtis.v2i1.217

Koerniawan, M. D., Aziiz, A. D., Ardiani, N. A., & Suhendri, S. (2020). Kenyamanan Termal Pekerja di Iklim Tropis-Lembap Indonesia (Issue August). ITB Press.

Lechner, N. (2015). Heating, Cooling, Lighting, Sustainable Methods for Architects. John Wiley & Sons, Inc. http://library1.nida.ac.th/termpaper6/sd/2554/19755.pdf

Nugraha, D. (2018). Efektivitas Ventilasi Rumah Lingkungan Padat Di Perumnas Depok Timur. 01(01), 27–31.

Nurjannah, A., & Alfata, M. N. F. (2020). Prototype of automated shading device: preliminary development. Engineering Journal, 24(4), 229–238. https://doi.org/10.4186/ej.2020.24.4.229

Passe, U., & Battaglia, F. (2015). Designing Spaces for Natural Ventilation. In Designing Spaces for Natural Ventilation. Taylor and Francis. https://doi.org/10.4324/9780203583470

Sari, W. E., & Andoni, H. (2019). Self-Kinetic Jalousie Sebagai Penerapan Teknologi Climate Responsive-Adaptable Architecture. Modul, 19(2), 119. https://doi.org/10.14710/mdl.19.2.2019.131-138

Satwiko, P. (2004). Solar-Wind Generated Roof Ventilation System (SiVATAS) for a Warm-Humid Climate. International Journal of Ventilation, 3(3), 209–218. https://doi.org/10.1080/14733315.2004.11683915

Satwiko, P. (2008). FISIKA BANGUNAN. Penerbit Andi. http://e-journal.uajy.ac.id/10816/

SNI 03-6572-2011. (2011). Tentang Tata cara perancangan sistem ventilasi dan pengkondisian udara pada bangunan gedung (pp. 1–55). http://staffnew.uny.ac.id/upload/132100514/pendidikan/perencanaan-pendingin.pdf

Sugini. (2014). Kenyamanan Termal Ruang, Konsep dan Penerapan pada Desain. Graha Ilmu.

Suryono. (2018). Teknologi Sensor, konsep Fisis dan Teknik Akuisisi Data Berbasis Mikrokontroler. Undip Press.

Yao, R., Li, B., & Liu, J. (2009). A theoretical adaptive model of thermal comfort - Adaptive Predicted Mean Vote (aPMV). Building and Environment, 44(10), 2089–2096. https://doi.org/10.1016/j.buildenv.2009.02.014

Yeny, A., & Hidayat, M. S. (2019). KAJIAN PENGGUNAAN VENTILASI ALAMI TERHADAP KENYAMANAN TERMAL RUANG KELAS (Studi Kasus : Sdn Pondok Jagung 1 Tangerang Selatan). Vitruvian, 8(3), 141. https://doi.org/10.22441/vitruvian.2019.v8i3.005

Downloads

Published

2021-06-28

How to Cite

Mufidah, M., Purwanto, L., & Sanjaya, R. (2021). Adaptasi Kinerja Bangunan Rumah Tinggal dengan Ventilasi Atap Responsif. RUAS, 19(1), 80–91. https://doi.org/10.21776/ub.ruas.2021.019.01.7